Case Studies
Proven Performance in Real-World Applications
Electric Vehicles
Fleet Electrification: 40-Vehicle Delivery Van Conversion
Urban Logistics Operator (North Germany)
14 weeks
Delivery timeline
40
Units supplied
Challenge
A regional logistics operator was converting a 40-vehicle diesel delivery fleet to electric. The challenge: the vans required 80 kWh packs that fit within the existing van floor template, support 2C fast charging for mid-shift top-up, and maintain 200 km range in winter conditions (-15°C).
Solution
Nordische designed a modular 80 kWh pack using prismatic NMC cells in a floor-integrated structural enclosure. Liquid thermal management maintained cell temperature above 10°C in sub-zero ambient through pre-conditioning triggered by fleet management software. BMS integrated with the operator's telematics via CAN bus.
Results
- 220 km winter range achieved (vs 195 km target)
- 2C fast charge to 80% in 24 minutes
- 15,000 km per vehicle average with zero degradation events
- 38% reduction in total fleet energy cost vs diesel baseline
Renewable Energy Storage
2 MWh Grid-Edge Storage for 8 MW Solar Farm
Solar Developer (Brandenburg, Germany)
18 weeks
Delivery timeline
40
Units supplied
Challenge
A solar farm developer needed grid-edge storage to maximize self-consumption, reduce curtailment, and provide 30-minute peak-shaving to avoid grid congestion penalties. The system needed to pass grid-code compliance for VDE-AR-N 4105 certification.
Solution
Deployed 2 MWh of rack-mounted LFP systems in weatherproof outdoor enclosures. SunSpec-compatible BMS integrated directly with the existing SMA inverter cluster. Nordische engineering team managed the VDE-AR-N 4105 certification process end-to-end.
Results
- 94.5% round-trip efficiency achieved
- Grid curtailment reduced from 18% to under 3%
- VDE-AR-N 4105 certification completed in 6 weeks
- Projected payback period: 7.2 years (vs 9.5-year industry average)
Telecom Infrastructure
Lead-Acid Replacement: 220-Tower Backup Power Upgrade
Telecom Tower Operator (Germany)
6 weeks
Delivery timeline
220
Units supplied
Challenge
A tower operator managing 220 outdoor towers across northern Germany was spending €380,000 annually on lead-acid replacement cycles and maintenance visits. High-temperature failures were causing an average of 2.3 outage events per tower per year.
Solution
Nordische supplied drop-in LFP replacement modules with passive thermal management rated to +60°C ambient. Remote SOH monitoring via cellular module eliminated scheduled visits. Installation was completed by the operator's own teams using Nordische installation guides.
Results
- Annual maintenance cost reduced by 71% (€270k/year saving)
- Outage events reduced to 0.1 per tower per year
- 10-year design life vs 3.5-year lead-acid average
- Installation completed across all 220 towers in 8 weeks
Your Application Could Be Next
Share the operating challenge and we will shape the battery architecture, compliance path, and delivery plan around it.
Your information is never shared. Read our Privacy Policy.